| dc.contributor.author | Matsitsi, Muthama S. | |
| dc.contributor.author | Linturi, James M. | |
| dc.contributor.author | Kebwaro, Jeremiah M. | |
| dc.contributor.author | Omonya, Felix W. | |
| dc.contributor.author | Mutua, John O. | |
| dc.date.accessioned | 2026-11-06T10:00:47Z | |
| dc.date.available | 2026-11-06T10:00:47Z | |
| dc.date.issued | 2026-10 | |
| dc.identifier.citation | Applied radiation and isotopes, volume 236, article no. 112747, 2026 | en_US |
| dc.identifier.uri | https://www.sciencedirect.com/science/article/abs/pii/S0969804326003313 | |
| dc.identifier.uri | https://repository.seku.ac.ke/handle/123456789/8463 | |
| dc.description | DOI: 10.1016/j.apradiso.2026.112747 | en_US |
| dc.description.abstract | The patient is the primary source of occupational scatter radiation in diagnostic radiology, necessitating characterization of site-specific scatter dose to guide accurate implementation of protection measures. The study assessed the levels and spatial distribution of scatter doses by recreating a full-scale 3D Geant4 Monte Carlo code of the diagnostic X-ray room at Kitui County Level V Hospital. Simulations were performed at 120 kVp exposures, and the spatial scatter absorbed dose was scored at designated operator positions P0–P7 ranging from 0.25 m to 2.0 m at a height of 1.0 m for ambient dose equivalent H(10) calculations. The model was validated using a calibrated NT6102 survey meter under matched beam conditions. Agreement between experimental and simulated dose rates was within ±10 %, suggesting the model can be used reliably in dose estimations. Following validation, the model was applied to evaluate the effects of varying tube potential, field size, operator source distance, a mobile lead glass barrier, and protective gear during exposure. The combined practical optimization strategies reduced the scatter dose significantly by over 90 %. Increasing distance from 0.25 m to 2.0 m reduced scatter dose by over 97 %. The results demonstrate that the use of lead aprons and increased operator distance are quantitatively effective in reducing occupational dose, consistent with ALARA principles. | en_US |
| dc.language.iso | en | en_US |
| dc.subject | monte carlo simulation | en_US |
| dc.subject | monte carlo simulation | en_US |
| dc.subject | geant4 | en_US |
| dc.subject | diagnostic x-ray | en_US |
| dc.subject | occupational dosimetry | en_US |
| dc.subject | scatter radiation | en_US |
| dc.title | Monte Carlo simulation of scatter radiation dose in a diagnostic x-ray room at Kitui County level v hospital, Kenya | en_US |
| dc.type | Article | en_US |