Monte Carlo simulation of scatter radiation dose in a diagnostic x-ray room at Kitui County level v hospital, Kenya

Show simple item record

dc.contributor.author Matsitsi, Muthama S.
dc.contributor.author Linturi, James M.
dc.contributor.author Kebwaro, Jeremiah M.
dc.contributor.author Omonya, Felix W.
dc.contributor.author Mutua, John O.
dc.date.accessioned 2026-11-06T10:00:47Z
dc.date.available 2026-11-06T10:00:47Z
dc.date.issued 2026-10
dc.identifier.citation Applied radiation and isotopes, volume 236, article no. 112747, 2026 en_US
dc.identifier.uri https://www.sciencedirect.com/science/article/abs/pii/S0969804326003313
dc.identifier.uri https://repository.seku.ac.ke/handle/123456789/8463
dc.description DOI: 10.1016/j.apradiso.2026.112747 en_US
dc.description.abstract The patient is the primary source of occupational scatter radiation in diagnostic radiology, necessitating characterization of site-specific scatter dose to guide accurate implementation of protection measures. The study assessed the levels and spatial distribution of scatter doses by recreating a full-scale 3D Geant4 Monte Carlo code of the diagnostic X-ray room at Kitui County Level V Hospital. Simulations were performed at 120 kVp exposures, and the spatial scatter absorbed dose was scored at designated operator positions P0–P7 ranging from 0.25 m to 2.0 m at a height of 1.0 m for ambient dose equivalent H(10) calculations. The model was validated using a calibrated NT6102 survey meter under matched beam conditions. Agreement between experimental and simulated dose rates was within ±10 %, suggesting the model can be used reliably in dose estimations. Following validation, the model was applied to evaluate the effects of varying tube potential, field size, operator source distance, a mobile lead glass barrier, and protective gear during exposure. The combined practical optimization strategies reduced the scatter dose significantly by over 90 %. Increasing distance from 0.25 m to 2.0 m reduced scatter dose by over 97 %. The results demonstrate that the use of lead aprons and increased operator distance are quantitatively effective in reducing occupational dose, consistent with ALARA principles. en_US
dc.language.iso en en_US
dc.subject monte carlo simulation en_US
dc.subject monte carlo simulation en_US
dc.subject geant4 en_US
dc.subject diagnostic x-ray en_US
dc.subject occupational dosimetry en_US
dc.subject scatter radiation en_US
dc.title Monte Carlo simulation of scatter radiation dose in a diagnostic x-ray room at Kitui County level v hospital, Kenya en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search Dspace


Browse

My Account