Electrochemical detection of glyphosate herbicide using horseradish peroxidase immobilized on sulfonated polymer matrix

Show simple item record

dc.contributor.author Owino, Joseph H.
dc.contributor.author Songa, Everlyne A.
dc.contributor.author Arotiba, Omotayo A.
dc.contributor.author Jahed, Nazeem
dc.contributor.author Baker, Priscilla G. L.
dc.contributor.author wuoha, Emmanuel I. I
dc.date.accessioned 2015-07-30T08:27:41Z
dc.date.available 2015-07-30T08:27:41Z
dc.date.issued 2009-06
dc.identifier.citation Bioelectrochemistry Volume 75, Issue 2, June 2009, Pages 117–123 en_US
dc.identifier.issn 1567-5394
dc.identifier.uri http://www.sciencedirect.com/science/article/pii/S1567539409000401
dc.identifier.uri http://repository.seku.ac.ke/handle/123456789/1352
dc.description doi:10.1016/j.bioelechem.2009.02.007 en_US
dc.description.abstract This paper describes the use of horseradish peroxidase (HRP) based biosensor for novel detection of glyphosate herbicide. The biosensor was prepared by electrochemically depositing poly(2,5-dimethoxyaniline) (PDMA) doped with poly(4-styrenesulfonic acid) (PSS) onto the surface of a gold electrode followed by electrostatic attachment of the enzyme HRP onto the PDMA-PSS composite film. Fourier transform infrared (FTIR) and UV–Vis spectrometry inferred that HRP was not denatured during its immobilization on PDMA-PSS composite film. The biosensing principle was based on the determination of the cathodic responses of the immobilized HRP to H2O2, before and after incubation in glyphosate standard solutions. Glyphosate inhibited the activity of HRP causing a decrease in its response to H2O2. The determination of glyphosate was achieved in the range of 0.25–14.0 µg L− 1 with a detection limit of 1.70 μg L− 1. The apparent Michaelis–Menten constant (calculated for the HRP/PDMA-PSS biosensor in the presence and absence of glyphosate was found to be 7.73 µM and 7.95 µM respectively. en_US
dc.language.iso en en_US
dc.publisher Elsevier en_US
dc.subject Poly(2,5-dimethoxyaniline) en_US
dc.subject Poly(4-styrenesulfonic acid) en_US
dc.subject Horseradish peroxidase en_US
dc.subject Biosensor en_US
dc.subject Glyphosate en_US
dc.subject Herbicide en_US
dc.subject Inhibition en_US
dc.title Electrochemical detection of glyphosate herbicide using horseradish peroxidase immobilized on sulfonated polymer matrix en_US
dc.type Article en_US


Files in this item