Modelling of the impedimetric responses of an aflatoxin B1 immunosensor prepared on an electrosynthetic polyaniline platform

Show simple item record

dc.contributor.author Owino, Joseph H.
dc.contributor.author gnaszak, Anna I
dc.date.accessioned 2015-07-30T07:37:21Z
dc.date.available 2015-07-30T07:37:21Z
dc.date.issued 2007-07-20
dc.identifier.citation Analytical and Bioanalytical Chemistry July 2007, Volume 388, Issue 5-6, pp 1069-1074 en_US
dc.identifier.issn 1618-2642
dc.identifier.issn 1618-2650
dc.identifier.uri http://download.springer.com/static/pdf/845/art%253A10.1007%252Fs00216-007-1333-9.pdf?originUrl=http%3A%2F%2Flink.springer.com%2Farticle%2F10.1007%2Fs00216-007-1333-9&token2=exp=1438242431~acl=%2Fstatic%2Fpdf%2F845%2Fart%25253A10.1007%25252Fs00216-007-1333-9.pdf%3ForiginUrl%3Dhttp%253A%252F%252Flink.springer.com%252Farticle%252F10.1007%252Fs00216-007-1333-9*~hmac=c81a5204848df54996ef28254a70b208f518ce24033083212dc9680a3282fa68
dc.identifier.uri http://repository.seku.ac.ke/handle/123456789/1350
dc.description DOI 10.1007/s00216-007-1333-9 en_US
dc.description.abstract Aflatoxins are a group of mycotoxins that have deleterious effects on humans and are produced during fungal infection of plants or plant products. An electrochemical immunosensor for the determination of aflatoxin B1 (AFB1) was developed with AFB1antibody (AFB1-Ab) immobilized on Pt electrodes modified with polyaniline (PANi) and polystyrene sulphonic acid (PSSA). Impedimetric analysis shows that the electron transfer resistances of the Pt/PANi–PSSA electrode, the Pt/PANi–PSSA/AFB1-Ab immunosensor and Pt/PANi–PSSA/AFB1-Ab incubated in bovine serum albumin (BSA) were 0.458, 720 and 1,066 kΩ, respectively. These results indicate that electrochemical impedance spectroscopy (EIS) is a suitable method for monitoring the change in electron transfer resistance associated with the immobilization of the antibody. Modelling of EIS data gave equivalent circuits which showed that the electron transfer resistance increased from 0.458 kΩ for the Pt/PANi–PSSA electrode to 1,066 kΩ for the Pt/PANi–PSSA/AFB1-Ab immunosensor, indicating that immobilization of the antibody and incubation in BSA introduced an electron transfer barrier. The AFB1 immunosensor had a detection limit of 0.1 mg/L and a sensitivity of 869.6 kΩ L/mg. en_US
dc.language.iso en en_US
dc.publisher Springer Verlag en_US
dc.subject Aflatoxin B1 en_US
dc.subject Aflatoxin B1 antibody en_US
dc.subject Electrochemical impedance spectroscopy en_US
dc.subject Differential pulse voltammetry en_US
dc.subject Immunosensor en_US
dc.title Modelling of the impedimetric responses of an aflatoxin B1 immunosensor prepared on an electrosynthetic polyaniline platform en_US