Please use this identifier to cite or link to this item: https://repository.seku.ac.ke/handle/123456789/1938
Full metadata record
DC FieldValueLanguage
dc.contributor.authorKiptoo, Michael K.-
dc.contributor.authorKimotho, James-
dc.contributor.authorNyairo, Edna-
dc.contributor.authorOchwoto, Missiani-
dc.contributor.authorNzioka, Nicholas-
dc.contributor.authorOgolla, Francis-
dc.contributor.authorNg'ang'a, Zipporah W.-
dc.date.accessioned2016-02-18T12:29:13Z-
dc.date.available2016-02-18T12:29:13Z-
dc.date.issued2015-02-15-
dc.identifier.citationAmerican Journal of Internal Medicine Volume 3, Issue 1, January 2015, Pages: 23-27en_US
dc.identifier.issn2330-4316 (Print)-
dc.identifier.issn2330-4324 (Online)-
dc.identifier.urihttp://article.sciencepublishinggroup.com/pdf/10.11648.j.ajim.20150301.14.pdf-
dc.identifier.urihttp://repository.seku.ac.ke/handle/123456789/1938-
dc.descriptionDOI: 10.11648/j.ajim.20150301.14en_US
dc.description.abstractBackground: The HIV Lateral Flow Tests (LFTs) provide a good compromise between accuracy, cost, speed and overall effectiveness. Objective: This study assessed the laboratory performance of the LFTs in the current National HIV Testing Algorithm in Kenya. Methods: Four hundred blood samples, 145 HIV positives and 255 HIV negatives, were collected from the Regional Blood Transfusion Centers in Kenya. They were analyzed using five LFTs, three of which were in the HIV Testing Algorithm in Kenya. Samples were also tested using Vironostika™ Uni-Form II Ag/Ab ELISA as a Gold Standard. The decision on the HIV status of the samples was determined by consensus status of the five LFTs. Diagnostic sensitivity (D-SN), specificity (D-SP), Positive Predictive Value (PPV) and Negative Predictive Value (NPV) were then computed together with relative Analytical sensitivity each LFT. Results: The three LFTs in the HIV Testing Algorithm in Kenya (KHB Colloidal Gold, First Response™ 1-2.0 and Uni-Gold™ HIV test) showed a D-SN of 100% (95% CI: 97.4-100.0), 96.4% (95% CI: 91.8 - 98.8) and 100% (95% CI: 97.4-100.0) respectively in relation to the Consensus status with LFTs. However, Determine™ HIV-1/2 showed the highest Analytical sensitivity when compared with two other kits in HIV Testing Algorithm in Kenya and Aware™ HIV-1/2 BSP kit. Conclusion: Though the LFTs in the current HIV Testing Algorithm in Kenya show high performance profiles, Determine™ HIV-1/2 showed higher Analytical sensitivity profile than the two HIV Screening and confirmation test kits. There is a need of reconsidering the financial savings (of 10-16%) vis-ȃ-vis the possibilities of missing HIV positive cases in the current HIV Testing Algorithm in Kenyaen_US
dc.language.isoenen_US
dc.publisherScience publishing groupen_US
dc.subjectlateral Flow Testsen_US
dc.subjectHIVen_US
dc.subjectTesting Algorithm in Kenyaen_US
dc.subjectSensitivityen_US
dc.subjectPredictive Valueen_US
dc.subjectSpecificityen_US
dc.titleLaboratory Evaluation of the Validity of the Current HIV Testing Algorithm in Kenyaen_US
dc.typeArticleen_US
Appears in Collections:School of Science and Computing (JA)

Files in This Item:
File Description SizeFormat 
Kiptoo_Laboratory Evaluation...pdfabstract94.88 kBAdobe PDFThumbnail
View/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.