dc.contributor.authorOwino, Joseph H.-
dc.contributor.authorgnaszak, Anna I-
dc.date.accessioned2015-07-30T07:37:21Z-
dc.date.available2015-07-30T07:37:21Z-
dc.date.issued2007-07-20-
dc.identifier.citationAnalytical and Bioanalytical Chemistry July 2007, Volume 388, Issue 5-6, pp 1069-1074en_US
dc.identifier.issn1618-2642-
dc.identifier.issn1618-2650-
dc.identifier.urihttp://download.springer.com/static/pdf/845/art%253A10.1007%252Fs00216-007-1333-9.pdf?originUrl=http%3A%2F%2Flink.springer.com%2Farticle%2F10.1007%2Fs00216-007-1333-9&token2=exp=1438242431~acl=%2Fstatic%2Fpdf%2F845%2Fart%25253A10.1007%25252Fs00216-007-1333-9.pdf%3ForiginUrl%3Dhttp%253A%252F%252Flink.springer.com%252Farticle%252F10.1007%252Fs00216-007-1333-9*~hmac=c81a5204848df54996ef28254a70b208f518ce24033083212dc9680a3282fa68-
dc.identifier.urihttp://repository.seku.ac.ke/handle/123456789/1350-
dc.descriptionDOI 10.1007/s00216-007-1333-9en_US
dc.description.abstractAflatoxins are a group of mycotoxins that have deleterious effects on humans and are produced during fungal infection of plants or plant products. An electrochemical immunosensor for the determination of aflatoxin B1 (AFB1) was developed with AFB1antibody (AFB1-Ab) immobilized on Pt electrodes modified with polyaniline (PANi) and polystyrene sulphonic acid (PSSA). Impedimetric analysis shows that the electron transfer resistances of the Pt/PANi–PSSA electrode, the Pt/PANi–PSSA/AFB1-Ab immunosensor and Pt/PANi–PSSA/AFB1-Ab incubated in bovine serum albumin (BSA) were 0.458, 720 and 1,066 kΩ, respectively. These results indicate that electrochemical impedance spectroscopy (EIS) is a suitable method for monitoring the change in electron transfer resistance associated with the immobilization of the antibody. Modelling of EIS data gave equivalent circuits which showed that the electron transfer resistance increased from 0.458 kΩ for the Pt/PANi–PSSA electrode to 1,066 kΩ for the Pt/PANi–PSSA/AFB1-Ab immunosensor, indicating that immobilization of the antibody and incubation in BSA introduced an electron transfer barrier. The AFB1 immunosensor had a detection limit of 0.1 mg/L and a sensitivity of 869.6 kΩ L/mg.en_US
dc.language.isoenen_US
dc.publisherSpringer Verlagen_US
dc.subjectAflatoxin B1en_US
dc.subjectAflatoxin B1 antibodyen_US
dc.subjectElectrochemical impedance spectroscopyen_US
dc.subjectDifferential pulse voltammetryen_US
dc.subjectImmunosensoren_US
dc.titleModelling of the impedimetric responses of an aflatoxin B1 immunosensor prepared on an electrosynthetic polyaniline platformen_US