<?xml version="1.0" encoding="UTF-8"?>
<feed xmlns="http://www.w3.org/2005/Atom" xmlns:dc="http://purl.org/dc/elements/1.1/">
<title>School of Engineering and Technology (JA)</title>
<link href="https://repository.seku.ac.ke/handle/123456789/24" rel="alternate"/>
<subtitle/>
<id>https://repository.seku.ac.ke/handle/123456789/24</id>
<updated>2026-11-10T03:40:18Z</updated>
<dc:date>2026-11-10T03:40:18Z</dc:date>
<entry>
<title>Optimizing straw incorporation depth as a plastic film alternative for sustainable maize production in semi-arid Eastern African Plateau</title>
<link href="https://repository.seku.ac.ke/handle/123456789/8465" rel="alternate"/>
<author>
<name>Munyasya, Alex N.</name>
</author>
<author>
<name>Indoshi, Sylvia N.</name>
</author>
<author>
<name>Mei, Fu-Jian</name>
</author>
<author>
<name>Cheruiyot, Wesly K.</name>
</author>
<author>
<name>Gisacho, Delphine N.</name>
</author>
<author>
<name>Wang, Yang</name>
</author>
<author>
<name>Chang, Nan</name>
</author>
<author>
<name>Li, Xian-Peng</name>
</author>
<author>
<name>Mburu, David M.</name>
</author>
<author>
<name>Tao, Hong-Yan</name>
</author>
<author>
<name>Turoop, Losenge</name>
</author>
<author>
<name>Nguluu, Simon N.</name>
</author>
<author>
<name>Shitanda, Douglas</name>
</author>
<author>
<name>Kavagi, Levis</name>
</author>
<author>
<name>Chepkorir, Uniter</name>
</author>
<id>https://repository.seku.ac.ke/handle/123456789/8465</id>
<updated>2026-11-09T08:43:47Z</updated>
<published>2027-03-01T00:00:00Z</published>
<summary type="text">Optimizing straw incorporation depth as a plastic film alternative for sustainable maize production in semi-arid Eastern African Plateau
Munyasya, Alex N.; Indoshi, Sylvia N.; Mei, Fu-Jian; Cheruiyot, Wesly K.; Gisacho, Delphine N.; Wang, Yang; Chang, Nan; Li, Xian-Peng; Mburu, David M.; Tao, Hong-Yan; Turoop, Losenge; Nguluu, Simon N.; Shitanda, Douglas; Kavagi, Levis; Chepkorir, Uniter
Optimizing the depth of straw incorporation is a promising strategy to reduce reliance on plastic film while sustaining crop productivity in dryland agriculture; however, its integrative effects still remain poorly understood. A two-year field experiment was conducted on the semi-arid Eastern African Plateau (EAP) from 2024 to 2025 growing seasons. The treatments were designed as follows: conventional flat bare planting (CK-1), ridge-furrow full plastic film mulching (CK-2), and ridge-furrow straw incorporation (10 t ha-¹) at depths of 20 cm, 40 cm, and 60 cm (BR-20, BR-40, BR-60). The data indicated that full film mulching (CK-2) achieved the best crop growth performance. Among non-film treatments, straw incorporation at 40 cm (BR-40) consistently outperformed BR-20 and BR-60. A single straw application exerted evident residual effects across growing seasons and effectively alleviated water stress even under the low rainfall conditions. BR-40 yielded the highest grain output and water use efficiency among all straw-incorporation groups. Despite BR-20 achieving an optimal topsoil aggregate structure in the 0–20 cm layer, mere surface soil improvement failed to maximize crop productivity. The superior performance of BR-40 was consistent with a depth-matching mechanism, whereby straw placement at 40 cm improved soil hydrothermal conditions, C-N-P availability, and microbial activity within a soil layer likely to overlap with an active maize root zone, thereby promoting more effective coupling between residue-derived resource availability and crop uptake. Life cycle assessment indicated higher greenhouse gas emissions under film mulching, yet BR-40 had an average yield-scaled carbon emission of 175.53 kg CO₂e t−1 grain, realizing low-carbon production while reducing plastic dependence. Thus, root zone matching serves as the core mechanism driving straw incorporation efficiency, and BR-40 is a promising tillage strategy to stabilize maize yield and reduce plastic consumption in EAP.
doi: 10.1016/j.still.2026.107538
</summary>
<dc:date>2027-03-01T00:00:00Z</dc:date>
</entry>
<entry>
<title>Metaheuristic-based optimal sizing of standalone PV-wind-BESS-EV hybrid renewable energy system</title>
<link href="https://repository.seku.ac.ke/handle/123456789/8464" rel="alternate"/>
<author>
<name>Gebru, Fsaha M.</name>
</author>
<author>
<name>Wekesa, Cyrus</name>
</author>
<author>
<name>Musau, Peter M.</name>
</author>
<author>
<name>Hasen, Suud A.</name>
</author>
<id>https://repository.seku.ac.ke/handle/123456789/8464</id>
<updated>2026-11-09T08:07:18Z</updated>
<published>2026-09-01T00:00:00Z</published>
<summary type="text">Metaheuristic-based optimal sizing of standalone PV-wind-BESS-EV hybrid renewable energy system
Gebru, Fsaha M.; Wekesa, Cyrus; Musau, Peter M.; Hasen, Suud A.
This study presents a comprehensive techno-economic optimization framework for a standalone Hybrid Renewable Energy System (HRES) comprising solar photovoltaic (PV), wind turbine (WT), battery energy storage system (BESS), and an electric vehicle (EV) fleet with bidirectional Vehicle-to-Grid (V2G) functionality. The study hypothesizes that integrating probabilistic EV behaviour and V2G capability into the sizing stage can reduce system cost while maintaining the required reliability for off-grid rural electrification. To capture the stochastic behaviour of EVs with V2G capability, EV arrival/departure times and state of charge (SOC) were modelled using probability distribution functions, and EV participation was incorporated directly into the sizing stage to quantify its impact on the levelized cost of energy (LCoE). The framework employs three metaheuristic optimization techniques, namely particle swarm optimization (PSO), grey wolf optimizer (GWO), and whale optimization algorithm (WOA), to minimize net present cost (NPC) and LCoE subject to a 5% loss of power supply probability (LPSP) reliability constraint. Seven years of hourly time-series data, including load demand, global horizontal irradiance (GHI), wind speed, ambient temperature, and probabilistic EV arrival/departure patterns, were aggregated into a representative one-year dataset to capture realistic operating conditions. A case study was conducted for a rural load of 1,556 households. PSO achieved the best solution, with an NPC of $14.51 million, an LCoE of 0.083 $/kWh, and an LPSP of 5.00%. The optimal configuration consists of 2,500 kWp PV, 397.5 kW WT, 22,138 kWh BESS, and an EV fleet of 300 vehicles providing 1,020 kWh of V2G-enabled storage, with wind energy contributing more than 55% of the annual supply. A comparative assessment with previous studies confirms that the proposed framework achieves competitive techno-economic performance while explicitly incorporating both EV with V2G functionality, which are often absent or only partially considered in existing HRES studies. Sensitivity analysis further shows that battery cost is the dominant factor affecting LCoE and NPC, whereas wind speed, solar irradiance, EV V2G participation, and EV fleet size have comparatively smaller impacts within the investigated range. The proposed framework demonstrates the synergistic benefits of V2G integration in lowering system costs and enhancing reliability, offering a replicable model for sustainable rural and off-grid electrification.
https://doi.org/10.1016/j.ecmx.2026.102141
</summary>
<dc:date>2026-09-01T00:00:00Z</dc:date>
</entry>
<entry>
<title>Development of a traveling wave-based protection scheme for power systems with high penetration of renewable energy sources using a hybrid independent component analysis-support vector machine algorithm</title>
<link href="https://repository.seku.ac.ke/handle/123456789/8458" rel="alternate"/>
<author>
<name>Mramba, Samson K.</name>
</author>
<author>
<name>Musau, Peter M.</name>
</author>
<author>
<name>Nyete, Abraham M.</name>
</author>
<id>https://repository.seku.ac.ke/handle/123456789/8458</id>
<updated>2026-11-03T06:41:08Z</updated>
<published>2024-01-01T00:00:00Z</published>
<summary type="text">Development of a traveling wave-based protection scheme for power systems with high penetration of renewable energy sources using a hybrid independent component analysis-support vector machine algorithm
Mramba, Samson K.; Musau, Peter M.; Nyete, Abraham M.
The bulk integration of renewable energy sources into the power grid brings about fresh challenges in grid protection, notably in the modification of fault levels. Also, the intermittent nature of renewable energy source inputs makes it challenging for traditional protection methods like overcurrent and distance relays to reliably safeguard these systems. This study introduces an Independent Component Analysis-Support Vector Machine-based protection system tailored to tackle the protection issues arising from renewable energy integration. This method was developed and tested on a 50kV 180km transmission line that was highly penetrated with solar photovoltaics, simulated in MATLAB/Simulink. Simulations were conducted for different fault types, signal noise levels, and fault resistances. The simulation results were then compared with the results of other methods published in available literature. The accuracy of the Independent Component Analysis-Support Vector Machine algorithm in determining the location of faults for the different scenarios was above 99.7%. The fault classification accuracy ranged between 99% and 100% for different levels of signal to noise ratio. Although the method is not as accurate when applied to power systems with high penetration of renewable energy sources as opposed to when applied to conventional power systems, the simulation results are satisfactory since they are higher than 99% which is the accuracy threshold for fault location and classification.
DOI: 10.51583/IJLTEMAS
</summary>
<dc:date>2024-01-01T00:00:00Z</dc:date>
</entry>
<entry>
<title>Performance evaluation of HEC-HMS for streamflow simulation in a poorly gauged semiarid catchment: Perkerra River, Kenya</title>
<link href="https://repository.seku.ac.ke/handle/123456789/8395" rel="alternate"/>
<author>
<name>Jeptum, Irine</name>
</author>
<author>
<name>Raude, James M.</name>
</author>
<author>
<name>Kiptala, Jeremiah K.</name>
</author>
<author>
<name>Cheruiyot, Charles K.</name>
</author>
<id>https://repository.seku.ac.ke/handle/123456789/8395</id>
<updated>2026-07-09T08:14:47Z</updated>
<published>2026-01-01T00:00:00Z</published>
<summary type="text">Performance evaluation of HEC-HMS for streamflow simulation in a poorly gauged semiarid catchment: Perkerra River, Kenya
Jeptum, Irine; Raude, James M.; Kiptala, Jeremiah K.; Cheruiyot, Charles K.
Hydrological models are essential for water resources planning, infrastructure development, and drought or flood risk management, yet their application in semiarid, data-scarce catchments remains challenging due to high spatial variability and limited observations. This study evaluated the performance of the HEC-HMS model for streamflow simulation in the Perkerra River catchment, Kenya. Model calibration was conducted using observed streamflow data from the Perkerra gauging station for the period January 2019 to December 2022, while validation was performed using data from January to December 2023. The validated and optimized model was subsequently applied to simulate streamflow at the Tigeri and Narosura stations within the catchment. Model performance was assessed using the Nash–Sutcliffe efficiency (NSE), root mean square error (RMSE), percent bias (PBIAS), RSR, and coefficient of determination (R2 ). NSE values 0.682 and 0.706 with low PBIAS values −4.45 and −1.80% during calibration and validation, respectively, indicated acceptable performance. Sensitivity analysis showed that baseflow parameters were the most influential, followed by impervious area, curve number, time of concentration, and storage coefficient. Overall, the results demonstrated that HEC-HMS could reliably simulate streamflow in the Perkerra catchment and had strong potential for application in poorly gauged semiarid basins, enabling drought preparedness.
doi: 10.2166/wcc.2026.061
</summary>
<dc:date>2026-01-01T00:00:00Z</dc:date>
</entry>
</feed>
